European Journal of Cardio-Thoracic Surgery, Vol 10, 408-411, Copyright © 1996 by European Association for Cardio-thoracic Surgery
J Aksnes, M Abdelnoor, ES Platou and NB Fjeld
OBJECTIVE: To search for predictors of mortality for patients in need of
intra-aortic balloon pump (IABP) support in the course of cardiac surgery.
METHODS: A retrospective study of possible pre- and perioperative risk
factors in 110 patients with mean age of 62 years (38-79). The IABP was
inserted preoperatively in 19 (17%) and perioperatively in 91 (83%).
RESULTS: Well known risk factors as advanced age (63.2/61.0; P = 0.25),
NYHA functional class (OR = 1.59; 95% CI 0.23 to 13.31), female sex (OR =
2.40; 95% CI 0.81 to 6.73), emergency surgery (OR = 0.63; 95% CI 0.21 to
1.80), low left ventricular ejection fraction (62.9/60.7; P = 0.53), or
elevated end diastolic pressure (19.4/21.0; P = 0.48), were not prognostic
of death. Perioperative insertion of the balloon pump (OR = 3.83; 95% CI
1.07 to 14.95), perioperative myocardial infarction (OR = 23.3; 95% CI 7.62
to 81.8), low cardiac output (OR = 7.53; 95% CI 2.43 to 24.11), and renal
failure (OR = 20.00; 95% CI 3.63 to 145), were strong predictors of death.
CONCLUSIONS: Outcome seemed to be determined by perioperative events rather
than preoperative risk factors. This could possibly explain the favourable
mortality rates seen in patients on IABP support prior to surgery compared
to patients who had IABP installed perioperatively.
ARTICLES
Mortality in patients supported by intra-aortic balloon pump in the course of cardiac surgery was related to perioperative myocardial infarction
Surgical Department A, Rikshospitalet, Oslo, Norway.
This article has been cited by other articles:
![]() |
A. S. Michalopoulos, S. Geroulanos, and S. D. Mentzelopoulos Determinants of Candidemia and Candidemia-Related Death in Cardiothoracic ICU Patients Chest, December 1, 2003; 124(6): 2244 - 2255. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Naughton and C. A. Bashour Mechanical Support After Cardiac Surgery Seminars in Cardiothoracic and Vascular Anesthesia, September 1, 2002; 6(3): 237 - 257. [Abstract] [PDF] |
||||
![]() |
J. T. Christenson, P. Badel, F. Simonet, and M. Schmuziger Preoperative Intraaortic Balloon Pump Enhances Cardiac Performance and Improves the Outcome of Redo CABG Ann. Thorac. Surg., November 1, 1997; 64(5): 1237 - 1244. [Abstract] [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |