European Journal of Cardio-Thoracic Surgery, Vol 11, 105-111, Copyright © 1997 by European Association for Cardio-thoracic Surgery
P Pinho, UO Von Oppell, J Brink and J Hewitson
OBJECTIVE: Pulmonary artery banding remains a palliative option for
patients with congenital heart disease and excessive pulmonary blood flow,
if there is unfavourable anatomy or frail condition. In contrast to more
developed countries, our patients at Red Cross Children's Hospital, Cape
Town, often present to medical services late and in poor nutritional
condition. We retrospectively reviewed patients undergoing pulmonary artery
banding to determine major variables that influenced long-term outcome.
METHODS: In a 10-year period ending June 1992, 135 consecutive patients
underwent pulmonary artery banding; 89 with ventricular septal defect type
non-mixing disorders, and 46 with mixing or complex disorders. The median
age was 3.0 months and weight 3.5 kg with 74.8% of patients weighing less
than the third percentile (NCHS adapted), and 39.3% had an additional
serious medical illness. RESULTS: Pulmonary banding mortality was 8.1%, and
was higher in neonates (22.2%), P = 0.04) but was not related to congenital
disorder, associated medical illness, or associated coarctation or
interrupted aortic arch. The pulmonary band was inadequate at follow-up in
28.9%, which occurred more commonly if banding was necessary before 3
months of age (41.5%, P = 0.003) but was not related to weight, congenital
disorder or associated respiratory infection. Sixty patients (44.4%) have
now proceeded to definitive repair with a mortality of 23.3%, which was
increased if the pulmonary band was inadequate at the time of definitive
repair (44.4%: P = 0.02), but was not related to the congenital disorder.
CONCLUSIONS: An inadequate pulmonary artery band adversely affects outcome
and demands further aggressive management prior to definitive repair.
ARTICLES
Pulmonary artery banding: adequacy and long-term outcome
Department of Cardiothoracic Surgery, School of Medicine, University of Cape Town, South Africa.
This article has been cited by other articles:
![]() |
C. Locker, J. A. Dearani, P. W. O'Leary, and F. J. Puga Endoluminal pulmonary artery banding: technique, applications and results. Ann. Thorac. Surg., August 1, 2008; 86(2): 588 - 594. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. Bautista-Hernandez, G. R. Marx, K. Gauvreau, J. E. Mayer Jr, F. Cecchin, and P. J. del Nido Determinants of Left Ventricular Dysfunction After Anatomic Repair of Congenitally Corrected Transposition of the Great Arteries Ann. Thorac. Surg., December 1, 2006; 82(6): 2059 - 2066. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Sekarski, P. Fridez, A. F. Corno, L. K. von Segesser, and E. J. Meijboom Doppler-guided regulation of a telemetrically operated adjustable pulmonary banding system J. Am. Coll. Cardiol., September 1, 2004; 44(5): 1087 - 1094. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. P. J. Leeuwenburgh, P. H. Schoof, P. Steendijk, J. Baan, W. J. Mooi, and W. A. Helbing Chronic and adjustable pulmonary artery banding J. Thorac. Cardiovasc. Surg., February 1, 2003; 125(2): 231 - 237. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. J. Cohen, A. Tamir, S. Houri, B. Abegaz, E. Gilad, S. Omohkdion, D. Zabeeda, V. Khazin, A. Ciubotaru, and A. Schachner Save a child's heart: we can and we should Ann. Thorac. Surg., February 1, 2001; 71(2): 462 - 468. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Seddio, V. M. Reddy, D. B. McElhinney, W. Tworetzky, N. H. Silverman, and F. L. Hanley MULTIPLE VENTRICULAR SEPTAL DEFECTS: HOW AND WHEN SHOULD THEY BE REPAIRED? J. Thorac. Cardiovasc. Surg., January 1, 1999; 117(1): 134 - 140. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |