EJCTS Click here for details of sales representative
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Revanna, P.
Right arrow Articles by Watterson, K. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Revanna, P.
Right arrow Articles by Watterson, K. G.

European Journal of Cardio-Thoracic Surgery, Vol 11, 280-286, Copyright © 1997 by European Association for Cardio-thoracic Surgery


ARTICLES

The influence of free hand suturing technique and zero pressure fixation on the hydrodynamic function of aortic root and aortic valve leaflets

P Revanna, J Fisher and KG Watterson
Killingbeck Hospital, University of Leeds, UK.

OBJECTIVE: There is increasing interest in the use of stentless porcine bioprostheses implanted by the free hand suturing technique. However, preservation of the normal valve geometry and function is a matter of concern. This study has been conducted to investigate the influence of free hand insertion on the hydrodynamic function of the aortic valve. In particular, free sewn valves have been compared to whole root replacements for both fresh valves and zero pressure fixed bioprostheses. METHODS: Four sets of porcine aortic roots with six aortic roots in each set consisting of (A) fresh aortic roots, (B) fresh aortic valve inserted by free hand suturing technique in fresh aortic valve fixed in glutaraldehyde under zero pressure, inserted by free hand suturing technique in fresh aortic roots, and (D) aortic roots fixed in glutaraldehyde under zero pressure, were studied. Hydrodynamic function and leaflet bending deformations were analysed in a modified pulsatile flow simulator which incorporates the elastic aortic roots. RESULTS: The glutaraldehyde-treated roots were found to be less distensible than the fresh aortic roots, with a mean dilatation of only 8% compared with 43% for the fresh roots at 120 mmHg pressure. The other two groups of free sewn valves showed reasonably good dilatation of 38%. There was no significant difference between the two sets. The hydraulic effective orifice area (EOA) of the valve, which was derived from the flow and pressure measurements, was divided by the actual orifice area for the annulus to arrive at the performance index. The performance index for glutaraldehyde-fixed aortic root was the lowest, with an index of 0.47 compared with 0.91 for that of fresh roots, 0.61 for the fresh valve in fresh root and 0.50 for the glutaraldehyde-treated valve in fresh root. The mean pressure difference during the peak flow also associated the same order with 12 mmHg for the glutaraldehyde-fixed roots, 1.8 mmHg for the fresh roots, 5.3 mmHg for the fresh valve in fresh root and 7.7 mmHg for the glutaraldehyde-treated valve in fresh root. The free hand suturing technique altered the leaflet geometry and caused increased open leaflet bending deformations compared to the fresh root. Both groups of free sewn valves behaved better than the zero pressure fixed root. CONCLUSIONS: Alteration in leaflet biomechanics is likely to influence long-term valve durability.


This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
L. M. Jennings, A. El-Gatit, Z. L. Nagy, J. Fisher, P. G. Walker, and K. G. Watterson
Hydrodynamic function of the second-generation mitroflow pericardial bioprosthesis
Ann. Thorac. Surg., July 1, 2002; 74(1): 63 - 68.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
Z. L. Nagy, J. Fisher, P. G. Walker, and K. G. Watterson
THE EFFECT OF SIZING ON THE IN VITRO HYDRODYNAMIC CHARACTERISTICS AND LEAFLET MOTION OF THE TORONTO SPV* STENTLESS VALVE
J. Thorac. Cardiovasc. Surg., January 1, 1999; 117(1): 92 - 98.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1997 European Association for Cardio-Thoracic Surgery. Published by Elsevier. All rights reserved.