European Journal of Cardio-Thoracic Surgery, Vol 11, 676-681, Copyright © 1997 by European Association for Cardio-thoracic Surgery
M Gaudino, T Van Geldorp, W Daenen, P Kalmar and Y Goffin
OBJECTIVE: To compare the function in aortic position of cryopreserved
pulmonary homografts subjected to pulmonary hypertension with that of
normal cryopreserved pulmonary homografts. METHODS: Pulmonary valves (52)
were implanted in aortic position in different cardiothoracic centres. The
valves were classified as follows: Group I-pulmonary hypertension (procured
from recipients of heart/heart-lung transplantation, 31 valves), Group
II-normal pulmonary pressure (procured from cadavers and multiorgan donors,
21 valves). Regular echocardiographic follow-up was obtained by the
implanting centers. Significant echo changes were defined as insufficiency
> 2+ and/or stenosis producing a delta P > 30 mm Hg. RESULTS:
Pulmonary homografts showed the following significant echo changes: in the
Pulmonary Hypertension Group, 7, 27 and 33% at 12, 24 and 36 months,
respectively; in the normal PA Group 10, 37.5 and 80% at 12, 24 and 36
months, respectively. In both groups the most common echocardiographic
alteration was homograft insufficiency rather than stenosis. Thus,
pulmonary homografts subjected to long-term pulmonary hypertension have
significantly less echo changes than normal pulmonary homografts,
especially after 12 months (chi 2: P < 0.036). CONCLUSIONS: These
findings suggest that pulmonary valves subjected to pulmonary hypertension
might be more appropriate than normal pulmonary homograft for aortic valve
replacement, constituting a possible alternative in case of lack of aortic
valve homografts. However, the failure of two out of five valves in the
longer term must dictate caution while waiting further long-term results.
ARTICLES
Are pulmonary homografts subjected to pulmonary hypertension more appropriate for aortic valve replacement than normal pulmonary homografts? Results of echocardiography in a multicentric study
European Homograft Bank, Brussels, Belgium.
This article has been cited by other articles:
![]() |
D. R. Koolbergen, M. G. Hazekamp, E. de Heer, F. van Hoorn, H. A. Huysmans, J. A. Bruijn, and R. A.E. Dion Structural degeneration of pulmonary homografts used as aortic valve substitute underlines early graft failure Eur. J. Cardiothorac. Surg., November 1, 2002; 22(5): 802 - 807. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. K. Choudhary, A. Saxena, B. Dubey, and A. S. Kumar Pulmonary homograftShould it be used in the aortic position? J. Thorac. Cardiovasc. Surg., July 1, 2000; 120(1): 148 - 155. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Jashari, B. Van Hoeck, M. Gaudino, W. Daenen, T. Van Geldorp, P. Kalmar, and Y. Goffin Are pulmonary homografts which were subjected to pulmonary hypertension more appropriate for aortic valve replacement than normal pulmonary homografts? A long-term multicentric echography study Eur. J. Cardiothorac. Surg., February 1, 2000; 17(2): 140 - 145. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |