EJCTS Click here for details of sales representative
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cotrufo, M.
Right arrow Articles by Giannolo, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cotrufo, M.
Right arrow Articles by Giannolo, B.

European Journal of Cardio-Thoracic Surgery, Vol 2, 355-359, Copyright © 1988 by European Association for Cardio-thoracic Surgery


ARTICLES

Clinical results after cardiac valve replacement with the Sorin prosthesis. A 6-year experience

M Cotrufo, M Festa, A Renzulli, L de Luca, P Sante and B Giannolo
Medical and Surgical Institute of Cardiology, 1st Medical School, University of Naples, Italy.

The mechanical valve produced by Sorin is a modified tilting disc device. Between March 1979 and November 1985, 763 Sorin prostheses were implanted in 710 patients. The study has been restricted to 504 isolated mitral or aortic valves. There were 238 females and 266 males whose ages ranged from 2 to 71 years (mean 43.8). Follow-up is 99.23% and covers 1045 patient-years. No structural failure has been observed. In the aortic position, 282 Sorin prostheses were implanted with the large orifice orientated towards the right coronary sinus. Hospital mortality was 5% (14/282). Actuarial survival at 78 months was 94.68% +/- 1.6% with a linearized mortality rate of 1.7% patient-years. There were 11 late deaths (9 valve-related and 2 non valve-related). The linearized rate of occurrence of embolic events was 0.32 patient-years (2/268). Actuarial survival complication-free at 78 months was 90.88% +/- 2.83%. Preoperatively, 19.8% patients were in NYHA class II, 68.5% in III and 11.7% in IV; postoperatively, 79.3% patients were in NYHA class I, 19.5% in II and 1.2% in III. In the mitral position, 222 Sorin prostheses were implanted with the large orifice orientated anteriorly in 46 patients (group 1) and posteriorly-in 176 patients (group 2). Hospital mortality was 4.5% (10/222). Actuarial survival at 66 months was 93.25% +/- 2.1% with a linearized mortality rate of 2.8 patient- years. There were 12 late deaths (9 valve-related and 3 non valve- related). The 66-month actuarial freedom from embolic events was 95.8% +/- 1.89% with a linearized rate of occurrence of 1.44 patient- years.(ABSTRACT TRUNCATED AT 250 WORDS)


This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
D. R. Clarke
Presidential address: Value, viability, and valves
J. Thorac. Cardiovasc. Surg., July 1, 2002; 124(1): 1 - 6.