EJCTS Click here for details of sales representative
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Supplemental Videos
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Hitendu Dave
Jürg Grünenfelder
Marko Turina
Gregor Zünd
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cattin, P.
Right arrow Articles by Zünd, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cattin, P.
Right arrow Articles by Zünd, G.
Related Collections
Right arrow Cardiac - other

Eur J Cardiothorac Surg 2004;25:786-790
© 2004 Elsevier Science NL


Trajectory of coronary motion and its significance in robotic motion cancellation

Philippe Cattina*,1, Hitendu Daveb,1, Jürg Grünenfelderb, Gabor Szekelya, Marko Turinab, Gregor Zündb

a Computer Vision Laboratory, Swiss Federal Institute of Technology, ETH-Zurich, Gloriastrasse 35, 8092 Zurich, Switzerland
b Clinic Cardiovascular Surgery, University Hospital Zurich, Raemistrasse 100, 8091 Zurich, Switzerland

Received 10 October 2003; received in revised form 5 January 2004; accepted 7 January 2004.

* Corresponding author. Tel.: +41-1-632-25-29; fax: +41-1-632-11-99
e-mail: cattin{at}vision.ee.ethz.ch

Objectives: To characterize remaining coronary artery motion of beating pig hearts after stabilization with an ‘Octopus’ using an optical remote analysis technique. Methods: Three pigs (40, 60 and 65 kg) underwent full sternotomy after receiving general anesthesia. An 8-bit high speed black and white video camera (50 frames/s) coupled with a laser sensor (60 µm resolution) were used to capture heart wall motion in all three dimensions. Dopamine infusion was used to deliberately modulate cardiac contractility. Synchronized ECG, blood pressure, airway pressure and video data of the region around the first branching point of the left anterior descending (LAD) coronary artery after Octopus stabilization were captured for stretches of 8 s each. Several sequences of the same region were captured over a period of several minutes. Computerized off-line analysis allowed us to perform minute characterization of the heart wall motion. Results: The movement of the points of interest on the LAD ranged from 0.22 to 0.81 mm in the lateral plane (x/y-axis) and 0.5–2.6 mm out of the plane (z-axis). Fast excursions (>50 µm/s in the lateral plane) occurred corresponding to the QRS complex and the T wave; while slow excursion phases (<50 µm/s in the lateral plane) were observed during the P wave and the ST segment. The trajectories of the points of interest during consecutive cardiac cycles as well as during cardiac cycles minutes apart remained comparable (the differences were negligible), provided the hemodynamics remained stable. Inotrope-induced changes in cardiac contractility influenced not only the maximum excursion, but also the shape of the trajectory. Normal positive pressure ventilation displacing the heart in the thoracic cage was evident by the displacement of the reference point of the trajectory. Conclusions: The movement of the coronary artery after stabilization appears to be still significant. Minute characterization of the trajectory of motion could provide the substrate for achieving motion cancellation for existing robotic systems. Velocity plots could also help improve gated cardiac imaging.

Key Words: Off-pump • Coronary artery bypass • Robotics




This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
T. Watanabe, S. Omata, M. Odamura, M. Okada, Y. Nakamura, and H. Yokoyama
Three-dimensional quantification of cardiac surface motion: a newly developed three-dimensional digital motion-capture and reconstruction system for beating heart surgery.
J. Thorac. Cardiovasc. Surg., November 1, 2006; 132(5): 1162 - 1171.
[Abstract] [Full Text] [PDF]


Home page
ICVTSHome page
M. Lemma, A. Mangini, A. Redaelli, and F. Acocella
Do cardiac stabilizers really stabilize? Experimental quantitative analysis of mechanical stabilization
Interactive CardioVascular and Thoracic Surgery, June 1, 2005; 4(3): 222 - 226.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2004 European Association for Cardio-Thoracic Surgery. Published by Elsevier. All rights reserved.