EJCTS Click here for details of sales representative
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Eur J Cardiothorac Surg 2008;33:769-773. doi:10.1016/j.ejcts.2008.01.026
Copyright © 2008, European Association for Cardio-thoracic Surgery. Published by Elsevier. All rights reserved.

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Lindsay C.H. John
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by John, L. C.H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by John, L. C.H.
Related Collections
Right arrow Cardiac - other

Modified closure technique for reducing sternal dehiscence; a clinical and in vitro assessment

Lindsay C.H. John*

Department of Cardiothoracic Surgery, Kings College Hospital, Denmark Hill, London SE5 9RS, UK

Received 27 November 2007; received in revised form 10 January 2008; accepted 14 January 2008.

* Corresponding author. Tel.: +44 20 3299 4365; fax: +44 20 3299 3433. (Email: lindsay.john{at}kch.nhs.uk).

Objective: Although the incidence of sternal dehiscence is low its mortality can be high. An alternative technique is described (modified closure) which aims to redistribute the dehiscence force into the longer longitudinal axis rather than the shorter transverse axis, thereby maximising the closure strength. Four ethibond sutures, which interlock anteriorly, are used in addition to eight transverse sternal wires. The aim of the study was to assess the modified closure using both an in vitro and a clinical study. Methods: (a) In vitro study: A weight and traction pulley system applied a force of 0.1 kN to pairs of silicone rubber hemisterna approximated to each other using alternative closure techniques. The dehiscence tendency (DT) was measured as the amount of separation under tension. Using 10 pairs of hemisterna for each closure technique the measured DT for the modified closure (MC) was compare with those for each of five alternative closures (two figure-of-eight and four transverse sutures (2C), 6 (6T), 8 (8T), 10 (10T) and 12 transverse sutures (12T)). (b) Clinical study: The incidence of sternal dehiscence for the first 4 years of a consultants’ practice (using 8T) was compared with the second 4 years (using MC). Results: (a) Measured DT (mean ± SEM), (MC: 149 ± 14; 6T: 256 ± 13; 8T: 223 ± 9; 10T: 213 ± 13; 12T: 203 ± 8; 2C: 294 ± 15). DT was significantly smaller for MC (p < 0.003). (b) The incidence of dehiscence was significantly smaller in the second 4 years (MC) than in the first (8T): 0.2% (1/529) versus 1.6% (13/788); p = 0.01 Conclusions: In vitro and clinical studies suggest that the modified closure technique can reduce the incidence of sternal dehiscence.

Key Words: Sternum • Wound closure • Wound dehiscence







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2008 European Association for Cardio-Thoracic Surgery. Published by Elsevier. All rights reserved.